6.5.4 SOFT CALIBRATION OF THE BRAKE

When calibrating the brake, the Watt Sensor board MUST NEVER BE TURNED OFF, as the data
will NOT BE SAVED. Carry out brake calibration when powering the display with a PC or a power
bank to keep it from turning off.
Page 64
7
6
Figure 39
New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
6.
If the template does not enter or
if the brake is too high (the two
upper magnets do not touch the
template) the acorn nut (6) must
be adjusted until reaching the
correct position of the brake with
respect to the template.
7.
Then, lock the acorn nut with the
locknut (7).
If the acorn nut is worn, replace it
with a new one.