New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
11
Figure 165
Document uncontrolled when printed
10
9
10.
Insert the screw (11) to remove the cen-
tring pin. Insert the washer (10) and tight-
en the nut and the screw with a 19 mm
wrench and a 6 mm Allen wrench..
Work from both sides counteracting the
wrenches.
Finish fitting the item back onto the bike by follow-
ing the aforementioned procedure in the reverse or-
der (steps 1 - 4).
ATTENTION: If the Group Cycle has the
Watt Sensor ID, follow the procedure
described in paragraph "6.7 procedure
to follow if it is necessary to remove the
plate on which the Watt Sensor ID is
fixed", point 3.
Tighten the belt as indicated in "11.5.1 Tighten-
ing the transmission belt".
Calibrate the brake as indicated in "6.5 Brake
calibration".