New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
The procedure to follow is described below:
1-Click Next, to the lower right, to continue;
2 -When the DOS window appears, disconnect the USB cable; wait approx. 10 seconds; reconnect
the USB cable (identified with the red ring ) to the PC. This action makes it possible to turn the Watt
Sensor board off and back on.
3- Press Ctrl+C to proceed with the sw update.
At this point, a window appears that displays the sw update progress. Wait for the update to finish.
If the update was successful, the message appears: "Software successfully loaded: disconnect and
reconnect the USB plug (of the GC cable) again. Now install the calibration database if necessary".
Document uncontrolled when printed
Figure 93