New Group Cycle (D92):
Technical Service Guide - Rev. 5.1
shown in detail in the following figure. This procedure prevents the cables from being discon-
nected by being accidentally pulled.
7. Fasten the new Watt Sensor ID board to the box using the previously removed screws.
Figure 45
8. Fasten the cover (B) to the box, using the previously removed screws.
9. Fasten the Watt Sensor ID cover to the plate, using the previously removed screws.