Figure 5.8: Every 250 Hours
A - Upper Cross Auger U-joint 13
13. U-joint has an extended lubrication cross and bearing kit. Stop greasing when greasing becomes difficult or if
U-joint stops taking grease. Overgreasing will damage U-joint. Six to eight pumps are sufficient at first grease
(factory). Decrease grease interval as U-joint wears and requires more than six pumps.
147725
MAINTENANCE AND SERVICING
B - Upper Cross Auger Bearing (2 Places)
121