15. The ***pH Neutralizing Filter [29] is mounted in an accessible location to a vertical bulkhead
after the Charcoal Filter [28] and prior to the U.V. Sterilizer [30].
CAUTION: Product water may spill during filter element replacing. Therefore, Do Not
mount the pH Neutralizing filter above any electrical or electronic component
16. The ***UV Sterilizer [30] is mounted to a bulkhead directly after the
Charcoal Filter [28], or after the pH Neutralizing Filter [29] if used. The
U.V. Sterilizer should be mounted vertically with the electrical fitting on the
top. The U.V. should be plumbed with the inlet on the bottom and the
outlet on top. Horizontal mounting is acceptable with outlet port on top
(pointed up) to displace air. Do Not mount the U.V. Sterilizer with the
electrical fitting on the bottom. Refer to Page 66 of this section for
installation details.
15. The ***Discharge Rinse Clean Valve [37] is mounted in an accessible location between the
System Brine Discharge Outlet located at the System Control Panel and the Brine Discharge
Thru-Hull Fitting [22]. Mount this valve in an accessible location.
16. The ***Remote Controller [40] is mounted to a flat surface with appropriate cut out for flush mounting to the
flat surface. Mount the Remote Controller in a protected area away from water spray. Refer to dimensional
drawings in this Section 2.
17. The Soft Start [41] is mounted in close proximity to the System Salinity Controller.
Section 2 Page 59 of 68
Sea Recovery Ultra Whisper v3.0 June 2008