ELECTRICAL SEQUENCE:
POWER APPLIED TO THE SYSTEM
RESULTS IN
"POWER" lamp illuminated at the Touch Pad
"START" SWITCH PRESSED
RESULTS IN:
"POWER" lamp illuminated at the Touch Pad
"HPP" green lamp illuminated at the Main Printed Circuit Board
12 VDC present at the Main Printed Circuit Board Terminal Strip "TB1" position "HP"
12 VDC present at the Feed Pump Contactor coil
System voltage transfer across the Feed Pump Contactor terminals to the Feed Pump motor
Feed Pump motor starts and system is operational
"SYSTEM ON" lamp illuminated at the Touch Pad
Salinity of Product water is monitored
If product water salinity is greater than the factory set point "Water Quality" red LED illuminates
If product water salinity is lower than the factory set point "Water Quality" green LED illuminates
"DV" green lamp illuminated at the Main Printed Circuit Board (if the "Water Quality" green LED is
illuminated at the Touch Pad.
12 VDC present at Main Printed Circuit Board "TB1" position "DV"
12 VDC present at 3-Way Product Water Diversion Valve coil
3-Way Product Water Diversion Valve actuates and diverts potable water to the Post Filtration
12 VDC present at Main Printed Circuit Board "TB1" position "UV"
12 VDC present at Ultra Violet Sterilizer
Ultra Violet Sterilizer illuminates (is functioning).
"STOP" SWITCH PRESSED
RESULTS IN:
"POWER" lamp illuminated at the Touch Pad
"HPP" green lamp NOT illuminated at the Main Printed Circuit Board
12 VDC NOT present at the Main Printed Circuit Board Terminal Strip "TB1" position "HP"
12 VDC NOT present at the Feed Pump Contactor coil
System voltage NOT transferred across the Feed Pump Contactor terminals to the Feed Pump motor
Feed Pump motor is NOT operational
"SYSTEM ON" lamp NOT illuminated at the Touch Pad
Salinity of Product water is NOT monitored and "Water Quality" LED NOT illuminated
"DV" green lamp NOT illuminated at the Main Printed Circuit Board
12 VDC NOT present at Main Printed Circuit Board "TB1" position "DV"
12 VDC NOT present at 3-Way Product Water Diversion Valve coil
3-Way Product Water Diversion Valve NOT actuated
12 VDC NOT present at Main Printed Circuit Board "TB1" position "UV"
12 VDC NOT present at Ultra Violet Sterilizer
Ultra Violet Sterilizer NOT illuminates (is NOT functioning).
IF STOP SWITCH WAS PRESSED TWICE THE FRESH WATER FLUSH CYCLE WILL NOT BE ACTIVATED.
IF STOP SWITCH WAS PRESSED ONCE:
If Fresh Water Flush Option is installed
"FWF" green lamp on Main Printed Circuit Board flashes (illuminates on and off) for 90 minutes
"Fresh Water Flush" amber lamp on Touch Pad flashes for 90 minutes
After 90 minutes "FWF" green lamp on Main Printed Circuit Board illuminates steady for 6 to 25 minutes
during the Fresh Water Flush process
"Fresh Water Flush" amber lamp illuminates steady for 6 to 25 minutes during the Fresh Water Flush process
section 6 page 35 of 38
Sea Recovery Ultra Whisper Rev. A