Sea Recovery SRC Ultra Whisper Compact 200 Owner's Manual page 35

Table of Contents

Advertisement

Sea Recovery Ultra Whisper Rev. A
24. Product Water Manifold allows transfer
of product water flow through the
compaonets attached to it.
25. Temperature Compensated Salinity
Probe electronically determines
whether the salinity content of the
Product Water has decreased to the
"safe" level. This Salinity Probe
retains an accurate reading throughout
varying temperature ranges.
26. 3-Way Product Water Diversion Valve, Electric
Solenoid Actuated.
The Salinity Controller [39]
energizes this valve to the
"Potable" position when the
system produces water which
meets the low salinity
requirement.
If the Product Water being produced is "Un-
potable", high in salinity, then no signal is sent to
the valve and it remains in the normally open
position. The "fail safe" normally open position
diverts the un-potable Product Water to
discharge through the Brine Discharge Tee
Connector [22].
27. Flow Meter, Product Water. This flow-through
meter measures the rate of Product Water flow in
gallons per hour from the R.O. Membrane
Element [20].
28. Charcoal Filter is designed to remove
foul odors from the Product Water.
Sulfurous smell (rotten egg smell) is
caused by decaying biological matter
in the Feed Water section. Fresh
water flushing of the System helps to
minimize the source of this odor.
29. pH Neutralizer Filter*** The Product
Water produced by Reverse Osmosis
is slightly acidic. The pH Neutralizer
Filter neutralizes the pH of the
Product Water.
30. Ultra Violet Sterilizer*** sterilizes up to
99.9% of any virus,
bacteria and other
micro-organisms
which
may pass through the R.O. Membrane Element
[20]. The U.V. sterilizer is recommended if the
Product Water Storage Tank [32] is not otherwise
treated by means such as chlorination.
31. Potable Water Storage Tank Tube
Connector is used to connect the
Systems Potable Product Water output
to the Potable Water Storage Tank [32].
32. Potable Water Storage Tank** may be any
container suitable for storing Potable Water such
as existing water storage tanks.
E. FRESH WATER FLUSH & R.O. MEMBRANE
ELEMENT CLEANING & RINSING SECTION.
The Fresh Water Flush
rinses the high salinity
Feed Water from the
System with Fresh
Water. This process is
automatic at each shut
down of the system
and repeats
automatically every
7 days. Fresh Water Flushing replaces the sea water
in the system with less corrosive fresh water. This
reduces the biological growth that naturally occurs if
the Feed Water (sea water) is left to stand in the
System.
Optional manually operated Valves are also available
that allow for ease of rinsing and cleaning the R.O.
Membrane Element.
33. Fresh Water Flush Pump, included with the Fresh
Water Flush Assembly. The Fresh Water Flush
Pump draws fresh water from the Potable Water
Storage Tank and pushes the water, at 45 PSI,
through the Fresh Water Flush Charcoal Filter
and into the rest of the System.
34. Fresh Water Flush Carbon Filter, included with the
Fresh Water Flush Assembly. The Carbon Filter
removes particulate matter and chlorine from the
fresh water to prevent chlorine attack to the R.O.
Membrane Element [20].
35. Fresh Water Flush Check Valve, included with the
Fresh Water Flush Assembly. The Check Valve
routes the fresh water to the System and prevents
the fresh water from expelling out the Inlet Thru
Hull Fitting [1].
Not numbered on P&ID.
Cleaning and
Winterizing Pressure
Section 1 Page 12 of 16