CAUTION: Do not use water tank diversion valves in this line to fill more than one tank. If it is
absolutely necessary to use a diversion valve to fill more than one tank use only a "never closed"
type ball valve which allows water to flow regardless of the valve handle position. If a valve in this
line is closed during operation extensive damage to the system will occur. Damage caused to the
system due to installation of valves in the product water line is the responsibility and liability of
the installer and is not covered by the Sea Recovery warranty.
4. The Sea Strainer [4] is mounted in an accessible location below water level between the Inlet
Sea Cock Valve [2] and Feed Pump [6]. Allow at least 4 inches (10 cm) of clearance below
the bowl to access the mesh screen for cleaning or replacement.
5. The ***Inlet Rinse Clean Valve [36] is mounted in an accessible location below water
level between the Sea Strainer [4] Outlet and the ***Fresh Water Flush Check Valve
[35] Inlet if used, otherwise the Feed Pump [6] Inlet.
6. The Feed Pump [6] is mounted at or below water level to assist the pump in priming.
Mount the Feed Pump between the Sea Strainer [4] Outlet and the ***Plankton
Filter [7] Inlet if used, otherwise the Prefilter [13] Inlet.
It is best to mount the Feed Pump below water level to assist priming, and in an
accessible location to allow access for maintenance.
CAUTION: Do not mount the pump head vertically above the motor, as motor damage will occur if the pump
or it's fittings should develop a leak. Eventually, from use the pump seal will wear and leak requiring
replacement. Water damage to the motor, if mounted improperly, is the responsibility and liability of the
installer and not covered by Sea Recovery warranty.
CAUTION: Mounting of the Feed Pump above water level will cause a vacuum at the inlet of the pump and
will result in premature wear resulting from cavitation. Improper installation of the Feed Pump causing
excessive vacuum at the inlet of the pump resulting in cavitation and premature wear is the responsibility and
liability of the installer and not covered by the Sea Recovery warranty.
7. The ***Fresh Water Flush [34] Filter Canister with attached Flush Pump [33]
is mounted in an accessible location to a vertical surface between an UN-
PRESSURIZED line in the Potable Water system and the Fresh Water Flush
Check Valve [35]. Allow at least 4 inches (10 cm)of clearance below the bowl
for element replacement.
CAUTION: Potable water may spill during filter element replacing.
Therefore, Do Not mount the prefilter above any electrical or electronic
component
8. The ***Fresh Water Flush Check Valve [35] Assembly (lower right component in the above illustration) is
mounted vertically in close proximity to the Outlet of the Feed Water Pump [6] and the Inlet of the Plankton
Filter [7] or 25 micron Prefilter [13].
Section 2 Page 39 of 68
Sea Recovery Ultra Whisper v3.0 June 2008