19. Discard the rinse water in a safe,
environmentally friendly, and legal manner.
20. Perform a final rinse. Reconfigure the System
for a ONCE THROUGH DE-PRESSURIZED
RINSE. Refer to illustrations on page 6 and as
described in item "C" on page 8 & 9 of this
Section.
Reconnect the brine discharge line to the brine
discharge tee [22].
or
If the Clean/Rinse Outlet Valve [37] is installed
position it to discharge out towards the brine
discharge connector [22].
21. One final time, fill the Rinse/Clean Solution
Container [38] with non-chlorinated product
water.
22. Start the system. The rinse water rinses the
entire system and discharging to waste [22].
23. Just prior to depleting the rinse water from the
Rinse/Clean Solution Container [38] stop the
system by pressing the stop switch once to
initiate the Automated Fresh Water Flush cycle
every 7 days. Press the Stop switch twice to
abort the Automated Fresh Water Flush cycle.
24. Reconfigure the System for normal operation:
a. Reconnect the Sea Strainer [4] outlet line, or
reposition the Inlet Rinse/Clean Valve [36]
to normal operation position
b. Remove the Product Relief Tube Kit
c. Reconnect the High Pressure Hose [21]
The System may now be operated or left unattended
for up to 4 to 8 weeks. If the System will be stored
without use for longer than 8 weeks refer to Long
Term Storage Procedures explained in item 5.4
pages 12 & 13 of this section.
If the System will be stored in Freezing
Temperatures refer to Short Term Storage
Procedures item 5.3 in this section, or Long Term
Storage Procedures item 5.4, as appropriate to
Winterize the System.
section 5 page 16 of 16