5. The Front Control Panel Assembly [26]
should be located to allow quick access. Mount
the Front Control Panel Assembly (page 9.12)
to a bulkhead using the supplied 1/4"x 1" Type
"A" lag screws. The Product Manifold [18-20],
Inlet [6], and Outlet [8] Gauges have 1/4"
tubing entering/exiting below the Front Control
Panel. 50 feet of tubing is supplied in the
installation kit, for plumbing instructions see
page 2.11.
6. The brine discharge exits through the Hull
Discharge Fitting [28] that must be installed
above the water line. The reject water
assembly is supplied in the installation kit to
allow the brine discharge from the Energy
Transfer Device [12] and the 3-Way Diversion
Valve [20] to exit through the Hull Discharge
Fitting.
7.
4
Ultra Whisper Compact Standard Component Mounting
2
Feed Pump mounted
close to Inlet Sea Cock
Valve.
Section 2 Page 14 of 68
7. (Modular Only) Mount the Energy Transfer
Device (page 9.7) [12] to a flat surface using
the supplied 1/4" x 2" Type "A" screws and
rubber mounts. The Energy Transfer Device is
mounted horizontally and in an accessible
location to allow access for maintenance. The
inlet hoses must be accessible so that they can be
relocated during storage or cleaning operations.
Mount the Energy Transfer Device close to the
Pressure Vessel Assembly [16]. Check that the
supplied high-pressure hoses can readily be
assembled before mounting.
These instructions are also illustrated at the end of
the Chapter 2.2.
System Mounted on a
flat Surface
6