STEP 3 ELECTRICAL CONNECTIONS
1. 1. Remove the Front Cover from the system
controller to access the Main Terminal Strip and
PC Board.
2. Connect main power as shown in Chapter 7, using
cable recommendations. The main power cable is
inserted through one of the large Strain Reliefs on
the bottom of the controller enclosure (pages 9.17-
9.19). For AC Systems only, the boat's 12 VDC
power source is also inserted through a small
Strain Relief indicated on the diagram below.
3. Connect the Feed Pump [4] motor power through
the other large Strain Relief on the bottom of the
controller enclosure to terminals as indicated in
Chapter 7.
CONNECT ANY OPTIONAL ACCESSORIES
(Refer to Chapter 7, page 2.9 and page 6.6)
4. Connect the Fresh Water Flush Boost Pump using
the supplied cable. Loosen the FWF Strain Relief
on the Controller Enclosure and insert the cable.
Refer to Wiring Diagrams for connection inside
Controller.
5. Connect UV Sterilizer (illustrated on page 9.15)
[22] using supplied purple cable. Loosen the other
small Strain Relief on the bottom of the
Controller Enclosure and insert the Purple cable.
Connect to the PC Board.
Remote Control: Close supplied Square Relief
6.
around the flat cable and snap together. Insert
into square cutout on bottom of Controller.
Connect other end to modular plug on PC Board.