Sea Recovery Ultra Whisper Rev. A
CAUTION: The Sea Recovery System must not be tied into another existing auxiliary water line already
supplying another accessory on the boat. Connecting the Sea Recovery System into a Thru-Hull fitting
already supplying other equipment will cause the Sea Recovery System to draw air, or cavitate leading to
continual system shut down, or may starve the other equipment.
CAUTION: If the Sea Recovery System is connected to a Sea Chest or Stand Up Pipe DO NOT plumb the Sea
Recovery System feed line to the "top" of the Sea Chest or Stand Up Pipe. If plumbed into the top of these
feed water arrangements the Sea Recovery System will experience continual shut down do to air inducement
into the System. Plumb the Sea Recovery System to the "bottom" of such feed water arrangements to ensure
a continual air free supply of feed water to the System.
The resulting failure of the System to remain in operation due to any of the above improper installation is the
liability of the installer, and is not covered by the Sea Recovery warranty.
3. Inlet Sea Cock Valve [2] Quarter turn ball valve min. ½" size, with a ½" MNPT connection for mating to the
supplied 1/2" FNPT fitting.
4. Brine Discharge Thru Hull Fitting [23] minimum ½" size with a ½" MNPT connection for mating to the
supplied 1/2" FNPT fitting. The Brine Discharge Thru Hull Fitting should be installed above water level. No
valves should be installed in this line. Damage to and failure of the system due to a closed valve will not be
covered by the Sea Recovery Warranty.
5. Connection of the Potable Water Storage Tank Tube Connector [31] to the boat's Potable Water Storage Tank
[32] requires a 1/4" FNPT connection for mating to the supplied 1/4" MNPT fitting. In order to avoid
problems such as reverse flow (osmosis) from the tank to the system and chlorination attack of the R.O.
Membrane Element [20], the fitting must terminate above the maximum water level. Tying into the tank fill
line is a good choice. No valves should be installed in this line. Damage to and failure of the system due to a
closed valve will not be covered by the Sea Recovery Warranty.
6. Connection of the Sea Recovery Fresh Water Flush sub assembly to the boat's un-pressurized Potable Water Line
[32] requires a 1/2" FNPT connection for mating to the 1/2" MNPT fitting supplied with the Fresh Water
Flush sub assembly.
7. Circuit Breaker with appropriate Amperage Rating. Refer to Section 8 of this Owner's Manual.
8. Properly sized Power Cables. Refer to Section 8 of this Owner's Manual.
9. An electrical power source capable of delivering the required constant voltage and cycles during start up and
operation of the System. Refer to Section 8 of this Owner's Manual.