d. Disconnect the Top and Bottom tube fittings
from the Ultra Violet Sterilizer [30] and
drain the Product Water from the U.V.
Sterilizer chamber. Reconnect the Top and
Bottom tube fittings back onto the U.V.
Sterilizer.
e. Disconnect the Fresh Water Line from the
Potable Water Storage Tank to the Fresh
Water Flush Pump [33] or if a valve is
installed in this line Close it to isolate the
potable water line from the Fresh Water
Flush Pump.
f. Remove the Fresh Water Flush Charcoal
Filter [34] bowl, drain and clean the inside of
the bowl. Replace the Fresh Water Flush
Charcoal Filter element with a new Sea
Recovery Fresh Water Flush Charcoal Filter
Element, and replace the bowl with new
element back onto the housing.
The System may now be left unattended for up to 3
to 6 months. With ideal conditions including a
relatively new R.O. Membrane Element, a clean
system prior to storage, cool temperatures, and no
leakage of storage chemical within the system, it
provides protection for up to 6 months. Adverse
conditions may provide less protection. Evaluate
these factors before determining the proper interval
between repeated rinsing and storage periods.
______________________________________
section 5 page 13 of 16
Sea Recovery Ultra Whisper Rev. A