IF The Pressure Gauges are all reading normal yet there is excessive Product Water Flow this could be caused by
an improper adjustment of the 3-way Product Water Diversion Solenoid Valve. If the 3-way Product Water
Diversion Solenoid Valve seats are improperly adjusted Brine Water can mix with Product Water. The
Product Water will be salty tasting.
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
30
20
40
50
10
PSI
60
0
-30
70
IN Hg
b. POSSIBLE CAUSE: 3-way Product Water Diversion Solenoid Valve [26] is out of adjustment.
1) Check the salinity of the Product Water after the product water manifold and prior to the Charcoal
Filter [28] using a hand held TDS meter, or taste the Product Water to determine if it is salty, above
1000 PPM TDS.
2) If the Product Water salinity is greater than 1000 PPM TDS and is flowing greater than normal, check
the 3-way Product Water Solenoid Diversion Valve [26] to ensure that it is properly adjusted and not
allowing bypass between the "good" and "bad" product water ports. Refer to section 7 of this
manual.
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
150
100
200
PSI
250
50
0
300
section 6 page 28 of 38
Sea Recovery Ultra Whisper Rev. A
[16]
PREFILTER OUTLET
OPERATING PRESSURE
ETD INLET
DEVELOPED BY THE ETD
PRESSURE GAUGE
0 - 300 PSI
150
100
200
PSI
250
50
300
0
[18]
0 - 1500 PSI
600
800
1000
400
PSI
1200
200
0
1400

Advertisement

Table of Contents
loading

Table of Contents