Connect main power to the assigned terminal block in
Chapter 7. The main power cable is inserted through a
large Strain Relief on the bottom of the controller
enclosure.
Connect the Feed Pump motor power through the other
large Strain Relief on the bottom of the controller
enclosure to the assigned terminal blocks as indicated in
Chapter 7.
Connect high-pressure switch cable to Printed Circuit
Board. The high-pressure switch cable is inserted through
FEED W ATER
INLET
Figure 2.2.7 Illustration of the Modular electrical connections
Section 2 Page 25 of 68
Sea Recovery Ultra Whisper Rev. A
the lower small Strain Relief on the side of the controller
enclosure
AC Systems only- Connect the boat's 12 VDC power
source through the small Strain Relief under the
controller enclosure and to the fuse terminals below the
terminal block assembly