5.2 CONFIGURING THE SYSTEM:
A. AUTOMATIC Fresh WATER FLUSH: If the
Automatic Fresh Water Flush Accessory is installed,
after a 90 minute delay, the Ultra Whisper is flushed
with Fresh Water automatically each time the
system is stopped after operation. The Ultra
Whisper may also be flushed with Fresh Water
simply by pressing the FWF switch at the Touch
Pad.
Refer to the two diagrams illustrated on page 4 of
this section.
1. The illustrations on page 4 of this section illustrate
the water flow when the Ultra Whisper is
performing an Automated Fresh Water Flush, if
the included Fresh Water Flush Accessory is
installed.
B. MANUAL FRESH WATER FLUSH: If the
Automated Fresh Water Flush Accessory is not
installed, or if a manual Fresh Water Flush is
preferred, when the instructions within this section
state "configure for Once Through Rinse", to Rinse
the System with Fresh Water for Short Term non
use in non freezing temperatures, proceed as follows:
Refer to the two diagrams illustrated on page 5 of
this section.
1. Configure the Suction line for a Once Through
process.
a. Close the Sea Cock Valve [2].
b. If the Optional Rinse/Clean Inlet Valve [36] is
not installed disconnect the hose from the
outlet line of the Sea Strainer [4] and place it
in the Rinse/Clean Solution Container [38] or
bucket.
or
If the Optional Rinse/Clean Inlet Valve [36] is
installed, position it to draw water from the
Rinse/Clean Container [38].
2. Configure the Brine Discharge line for a Once
Through process.
a. Connect the Brine Discharge Line from the
System to the Thru-Hull over board discharge
fitting [22], this is the normal connection for
normal operation.
Or
If the System is equipped with an Optional
Discharge Rinse/Clean Outlet Valve [37]
position this valve to discharge through the
Brine Discharge Connector [22], this is the
normal connection for normal operation.
C. ONCE THROUGH DE-PRESSURIZED RINSE:
When the instructions within this section state
"configure for Once Through De-pressurized Rinse"
used for once through flushing of Storage Chemical,
Winterizing Chemical, or rinse between R.O.
Membrane Cleaning proceed as follows:
Refer to the two diagrams illustrated on page 6 of
this section.
1. In order to relieve pressure during the Once
Through Winterizing Rinse process the Pressure
Relief Tube Kit must be installed.
a. Disconnect only one end of the High Pressure
Hose [21] MVA Outlet/Energy Transfer Device
Return either from the R.O. Membrane/Vessel
Assembly [20] Outlet (Brine Discharge end) or
from the ETD [17] Return Port "R" (which
ever is easier to access).
b. Connect the Product Relief Tube Kit to the
loose end of the High Pressure Hose [21] and
to the exposed fitting on the R.O.
Membrane/Vessel Assembly [20] Outlet or the
ETD [17] Return Port "R" fitting (which ever
fitting the High Pressure Hose [21] was
disconnected from).
c. Route the 1/4 inch O.D. Tube from the Pressure
Relief Tube Kit into the Rinse/Clean Solution
Container [38] or bucket.
2. Configure the Suction line for a Once Through
process.
a. Close the Sea Cock Valve [2].
b. Disconnect the outlet line from the Sea Strainer
[4] and place it in the Rinse/Clean Solution
Container [38].
Or
If the System is equipped with an Optional
Inlet Rinse/Clean Valve [36] between the Sea
section 5 page 8 of 16