Sea Recovery SRC Ultra Whisper Compact 200 Owner's Manual page 174

Table of Contents

Advertisement

Abnormality 2.
SYSTEM PRODUCTION, PRODUCT WATER FLOW, IS HIGHER THAN
NORMAL.
The Ultra Whisper System self adjusts the operating pressure, up or down accordingly, to produce the specified
amount of Product Water. Therefore, the System should never produce more Product Water than specified unless
one or more of the following has occurred:
a. There is a blockage in the Brine Discharge Line causing Brine Water by-pass into the Product Water
b. The 3-way Product Water Diversion Solenoid Valve is not properly adjusted
c. There is bypassing of the Feed Water into the Product Water due to a broken or worn Product Water O-
ring, a crack or imperfection in the High Pressure Vessel End Plug, or the R.O. Membrane Element is
damaged.
d. The System components have been mismatched
IF The Feed Pump Inlet Compound Vacuum/Pressure Gauge [5] registers Normal with slight vacuum or 0 (zero)
PSI, and the other 3 pressure gauges (Prefilter Inlet Pressure Gauge [12], Prefilter Outlet Pressure Gauge
[16], and Operating Pressure Gauge [18]) all register higher than normal this would indicate that there could
be a blockage in the Brine Discharge Line causing the excessive pressure readings and by-passing of Brine
Water into the Product Water through the 3-way Product Water Solenoid Diversion Valve resulting in excess
Product Water Flow.
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
20
10
PSI
0
-30
IN HG
a. POSSIBLE CAUSE: BLOCKAGE IN THE BRINE DISCHARGE LINE
2) Ensure that any valve in the Brine Discharge Line or at the Thru Hull Discharge Fitting [22] is full
OPEN.
3) Ensure that there are no kinks or other blockages in the Brine Discharge Line.
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
30
150
40
100
50
50
60
70
0
section 6 page 27 of 38
[16]
PREFILTER OUTLET
ETD INLET
PRESSURE GAUGE
0 - 300 PSI
100
200
PSI
250
50
300
0
Sea Recovery Ultra Whisper Rev. A
[18]
OPERATING PRESSURE
DEVELOPED BY THE ETD
0 - 1500 PSI
150
600
200
400
PSI
250
200
300
0
800
1000
PSI
1200
1400

Advertisement