the Membrane Element but also damages
the membrane surface.
CAUTION: DO NOT MIX DIFFERENT CLEANING
CHEMICALS TOGETHER. DO NOT USE DIFFERENT
CLEANING CHEMICALS TOGETHER AT THE SAME
TIME. MIX THE CLEANING CHEMICALS
SEPARATELY AND USE THEM SEPARATELY.
5.5.2 R.O. MEMBRANE ELEMENT CLEANING
INSTRUCTIONS:
Product Water Required, in U.S. Gallons, for
Cleaning of the R.O. Membrane Element:
Chemical
Rinse
Cleaning
water
water
required required
CC-1
5
5
CC-2
5
5
CC-3
5
5
1. Configure the System for a "Once Through De-
pressurized Rinse" using the Product Relief Tube
Kit as illustrated on page 6 of this section and as
described in item 5.2.C page 8 and 9 of this
section.
2. Close the Inlet Sea Cock Valve [2].
3. Clean the Sea Strainer [4] Mesh Screen.
4. Clean the Plankton Filter Element [7].
5. Replace the Pre-filtration Cartridges [13 & 14]
with new 25 and 5 micron Sea Recovery Pre-
filtration Elements.
6. Fill the Rinse/Clean Solution Container [38] with
non-chlorinated product water.
7. Start the system. The rinse water rinses the entire
system and discharging to waste [22].
8. Just prior to depleting the rinse water from the
Rinse/Clean Solution Container [38] stop the
system by pressing the stop switch twice to stop
the System and also to abort the Fresh Water
Flush Cycle.
9. Once again, fill the Rinse/Clean Solution
Container [38] with non-chlorinated product
water.
10. Add to the product water in the Rinse/Clean
Solution Container [38] one container (plastic
bottle 1.5 lbs) of Sea Recovery Membrane
Second
Final
Total
Rinse
Rinse
water
water
water
required
required
required
5
5
20
5
5
20
5
5
20
section 5 page 15 of 16
Sea Recovery Ultra Whisper Rev. A
Element Cleaning Compound SRC MCC 1, SRC
MCC 2, or SRC MCC 3 (only one chemical as
appropriate for the type of cleaning desired). DO
NOT ADD ANY OTHER CHEMICAL. DO NOT
MIX MORE THAN ONE CHEMICAL TO THE
WATER.
11. Mix and thoroughly dissolve the solution in the
Rinse/Clean Solution Container [38].
12. Configure the System for a "R.O. Membrane
Element Cleaning Closed Loop". Refer to
illustrations on page 7 of this section as described
on page 9 of this section.
Disconnect the brine discharge line from the
brine discharge tee [22] and place it into the
storage/cleaning container [38].
or
If the Clean/Rinse Outlet Valve [37] is installed
position it to return to the storage cleaning
container [38].
13. Operate the system by pressing the "Start"
Switch. The membrane cleaning solution flows
from the container, through the System, and
back into the container [38] in a closed loop
configuration.
14. After approximately one hour of circulation, stop
the system by pressing the Stop Switch twice
which will also disable the Fresh Water Flush
Cycle.
15. Discard the Cleaning Chemical Solution in a safe,
environmentally friendly, and legal manner.
16. To closed loop rinse the Cleaning Chemical from
the System, again Fill the Rinse/Clean Solution
Container [38] or bucket with 5 gallons of non
chlorinated product water.
17. Operate the system by pressing the "Start"
Switch. The rinse water flows from the
container, through the System, and back into the
container in a Closed Loop configuration.
18. After approximately 15 minutes of circulation,
stop the system by pressing the Stop Switch
twice which will also disable the Fresh Water
Flush Cycle.

Advertisement