If power is not interrupted, after the 6 to 25 minute Fresh Water Flush process "FWF" green lamp on Main
Printed Circuit Board flashes for 7 days
"Fresh Water Flush" amber lamp on Touch Pad flashes for 7 days
After 7 days "FWF" green lamp on Main Printed Circuit Board illuminates steady for 6 to 25 minutes during
the Fresh Water Flush process
"Fresh Water Flush" amber lamp illuminates steady for 6 to 25 minutes during the Fresh Water Flush process
etc.
If the System Stop Switch is pressed, or if power is interrupted the "FWF" green lamp on the Main Printed
Circuit Board turns off, the "Fresh Water Flush" amber lamp on the Touch Pad turns off, and the Fresh
Water Flush process will not initiate.
"FWF" SWITCH PRESSED WHEN SYSTEM IS NOT IN OPERATION BUT POWER TO THE SYSTEM IS PRESENT.
RESULTS IN:
"POWER" lamp illuminated at the Touch Pad
"FWF" green lamp on Main Printed Circuit Board illuminates steady for 6 to 25 minutes during the Fresh
Water Flush process
"Fresh Water Flush" amber lamp illuminates steady for 6 to 25 minutes during the Fresh Water Flush process
After the 6 to 25 minute Fresh Water Flush process "FWF" green lamp on Main Printed Circuit Board flashes
for 7 days
"Fresh Water Flush" amber lamp on Touch Pad flashes for 7 days
After 7 days "FWF" green lamp on Main Printed Circuit Board illuminates steady for 6 to 25 minutes during
the Fresh Water Flush process
"Fresh Water Flush" amber lamp illuminates steady for 6 to 25 minutes during the Fresh Water Flush process
etc.
If the System Stop Switch is pressed, or if power is interrupted the "FWF" green lamp on the Main Printed
Circuit Board turns off, the "Fresh Water Flush" amber lamp on the Touch Pad turns off, and the Fresh
Water Flush process will not initiate.
"FAULT RESET" SWITCH PRESSED
RESULTS IN:
"POWER" lamp illuminated at the Touch Pad
If the system shut down due to a high or low pressure condition at the time of shut down the "High/Low
Pressure" red lamp on the Touch Pad illuminates
Press the "FAULT RESET" switch to turn this lamp off.
Correct the cause of the High or Low pressure condition.