B. HIGH PRESSURE ABNORMALITIES:
High Pressure Abnormalities, excessive or higher than normal pressure at the R.O. Membrane Element as registered
on the High Pressure Gauge [18], can be caused by Low Temperature Feed Water, High Salinity Feed Water, Fouled
R.O. Membrane Element, a blockage in the Brine Discharge Line, and or a blockage in the Product Water Line.
Abnormality 1.
SYSTEM SHUTS DOWN DURING OPERATION OR IMMEDIATELY AFTER
STARTING AND THE HIGH/LOW PRESSURE FAULT LAMP IS
ILLUMINATED. THE HIGH/LOW PRESSURE FAULT LAMP DID NOT
ILLUMINATE INTERMITTENTLY (DID NOT BLINK) FOR 20 SECONDS
PRIOR TO THE SYSTEM SHUTTING DOWN.
Properly Position Valves
a) Ensure that the Sea Cock Valve [2] is fully open.
b) Ensure that the Inlet Rinse Clean Valve [36], if installed, is positioned towards the Sea Strainer [4]
normal operating position.
c) Ensure that the Discharge Rinse Clean Valve [37], if installed, is positioned towards the Sea Brine
Discharge Fitting [22] normal operating position.
d) Ensure that any valve in the Brine Discharge Line or at the Thru Hull Discharge Fitting [22] is full
OPEN.
e) Ensure that any valve in the Product Water Line is full OPEN.
f) Ensure that there are no kinks or other blockages in the Brine Discharge Line and or the Product Water
Line.
IF The Feed Pump Inlet Compound Vacuum/Pressure Gauge [5] registers Normal with slight vacuum or 0 (zero)
PSI, the Prefilter Inlet Pressure Gauge [12] registers higher than normal, the Prefilter Outlet Pressure Gauge
[16] registers higher than normal, and the Operating Pressure Gauge [18] also registers higher than normal.
This would indicate that the ETD is attempting to overcome a "restriction" of Product Water Flow caused by
one or more of the reasons stated above (Low Temperature Feed Water, High Salinity Feed Water, Fouled
R.O. Membrane Element, a blockage in the Brine Discharge Line, and or a blockage in the Product Water
Line).
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
30
20
10
PSI
0
-30
IN HG
a. POSSIBLE CAUSE: LOW TEMPERATURE FEED WATER.
1) The System may be operating and reacting normal in relationship to the Feed Water Salinity and
Temperature. Refer to the Salinity, Temperature and Operating Pressure Charts in Section 10 of this
manual to ensure that the System is being operated within the Feed Water Temperature limits stated,
and or that the resulting operating pressure is at the expected pressure according to the charts.
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
150
40
100
50
PSI
50
60
70
0
section 6 page 14 of 38
[16]
PREFILTER OUTLET
ETD INLET
PRESSURE GAUGE
0 - 300 PSI
150
100
200
PSI
250
50
300
0
Sea Recovery Ultra Whisper Rev. A
[18]
OPERATING PRESSURE
DEVELOPED BY THE ETD
0 - 1500 PSI
600
800
200
400
PSI
250
200
300
0
1400
1000
1200