Sea Recovery SRC Ultra Whisper Compact 200 Owner's Manual page 37

Table of Contents

Advertisement

Sea Recovery Ultra Whisper Rev. A
TOUCH PAD CONTROL DESCRIPTIONS:
SWITCHES
START: This switch initiates the start cycle of the Feed Pump
[6] and the System.
FRESH WATER FLUSH: This switch initiates the Fresh
Water Flush Cycle. When pressed, the Fresh Water Flush
Cycle begins and the Fresh Water Flush lamp illuminates
steady green.
STOP: This switch, when pressed, stops the System if it is in
operation or stops the Fresh Water Flush Cycle if it is in the
"stand by" mode or actually in the flushing mode. Each time
the system is stopped, the Fresh Water Flush system is
initiated as indicated by a steady illumination of the Fresh
Water Flush lamp. The Fresh Water Flush cycle is aborted by
pressing the Stop switch a second time.
FAULT RESET: This switch resets the High/Low Pressure
fault and allows the system to start.
INDICATION LAMPS:
Power: This lamp is illuminated when power is supplied to the
controller indicating that the System is receiving power from
the main power breaker.
System On: This lamp illuminates when the System has been
Started and is operating.
Fresh Water Flush: This lamp illuminates continually during
the Fresh Water Flushing operation. When the Fresh Water
Flush is in the stand-by mode, in between the flushing cycle
that repeats automatically every seven days, the lamp
illuminates intermittently on and off (blinks). If this lamp is
not illuminated when the System is not in operation the Fresh
Water Flush cycle has been terminated.
Product Water Quality: This lamp indicates the quality of the
water being produced by the system. A red illumination
indicates that the System is producing "un-potable" product
water that is being discharged over board. A green lamp
illuminates when the system is producing safe water (potable
water) that is being diverted to the potable water storage tank.
High/Low Pressure: The High/Low pressure fault lamp
illuminates when the system shuts down due to either a low-
pressure condition, or a high-pressure condition. During
operation if the Low Pressure Switch senses a low-pressure
condition, this lamp blinks for twenty seconds, and then the
system shuts down and the lamp remains illuminated until the
Fault Reset Switch is pressed. If the High Pressure Switch
senses a high pressure condition during operation the system
will shut down immediately and the lamp will illuminate until
the Fault Reset Switch is pressed.
Section 1 Page 14 of 16