7. The Fresh Water Flush [34] Filter Canister with attached Flush Pump [33] is
mounted in an accessible location to a vertical surface between an UN-
PRESSURIZED line in the Potable Water system and the Feed Pump [6]
Outlet. Allow at least 4 inches (10 cm)of clearance below the bowl for element
replacement.
CAUTION: Potable water may spill during filter element replacing.
Therefore, Do Not mount the prefilter above any electrical or electronic
component
8. The Fresh Water Flush Check Valve [35] Assembly (lower right component in the above illustration) is mounted
vertically in close proximity to the Feed Water Pump [6] Outlet and Plankton Filter [7] Inlet or 25 micron
Prefilter Inlet [13].
9. The ***Plankton Filter [7] is mounted in an accessible location to a vertical surface between
the Feed Pump [6] Outlet and the Pre Filter [13] Inlet which is mounted to the System
Frame. Allow at least 4 inches (10 cm) of clearance below the bowl for element replacement.
CAUTION: Feed water may spill during filter element replacing. Therefore, Do Not mount
the prefilter above any electrical or electronic component.
10. The Inline Tee Pressure Pick-Up [8] will be connected in line between the Feed Pump [6]
Outlet or Plankton Filter [7] Outlet and the 25 micron Prefilter [13] Inlet. Allow sufficient
space when mounting these components.
11. The Pre-filters [13 & 14] are mounted in an accessible location to a vertical
surface between the Plankton Filter [7] outlet and the Energy Transfer Device
[17]. Allow minimum 4 inches (10 cm) below the bowl for filter element
removal.
CAUTION: Feed water may spill during filter element replacing. Therefore, Do
Not mount the prefilter above any electrical or electronic component
Note: The Vacuum/Pressure gauge shown at the Prefilter Bracket is the Feed
Water Pump Inlet Vacuum/Pressure Gauge [5]. The Pressure Manifold [9], Low
Pressure Switch [10] and High Pressure Switch [11] are located behind and
mounted to the prefilter bracket.
12. The Inline Tee Pressure Pick-Up [15] will be connected in line between the 5 micron Prefilter
Outlet [14] and the ETD [17] Inlet. Allow sufficient space when mounting these components.