the time causing frequent shut down of the system and very frequent changing which will also lead to very high
cost of maintenance. Use of String Wound or Fiber type elements will only lead to user frustration and very
high maintenance costs. Use of third party prefilter elements will void any and all Sea Recovery warranty to
the High Pressure Pump, the ETD, and the R.O. Membrane Element.
To Clean or replace the Prefilter Element:
1. Unscrew the bowl counter clockwise.
2. Remove the Prefilter Pleated Cartridge Element from the bowl.
3. Remove the O-Ring from the top of the bowl and take care to not damage it.
4. Replace the Prefilter Pleated Cartridge Element with a new Sea Recovery element.
5. Wipe the O-Ring with a damp cloth.
6. Lubricate the O-Ring lightly using a sparingly amount of petroleum free O-Ring lubricant.
7. Place the O-Ring back onto the bowl.
8. Insert the new Prefilter Pleated Cartridge Element into the bowl.
9. Screw the bowl on clockwise hand snug to seal the O-Ring, do not use a wrench or other tool to tighten, do
not over tighten. Over tightening will damage the threads in the bowl or housing and over tightening will
cause removal to be difficult.
section 7 page 10 of 39