b. POSSIBLE CAUSE: DIRTY AND PLUGGED PLANKTON FILTER [7] ELEMENT.
1) Press Reset Fault Switch to reset and turn off the "High/Low Pressure" Fault Lamp.
2). Start the System
IF The Feed Pump Inlet Compound Vacuum/Pressure Gauge [5] registers normal (near or at 0 [zero] PSI, yet
the Prefilter Inlet Pressure Gauge [12], Outlet Prefilter Pressure Gauge [16], and Operating Pressure Gauge
[18] all register lower than normal this would indicate that the Plankton Filter [7] (if installed) is dirty and
requires cleaning.
This could also indicate that the feed water pump requires servicing. If the internal components of the feed
water pump have been cavitated or worn from abrasive particles in the feed water the pump will lose its
ability to maintain pressure and flow. Refer to Feed Water Pump troubleshooting later in this section.
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
30
20
40
50
10
PSI
60
0
-30
70
IN Hg
1. Clean the Plankton Filter Element [7]. Attempt to operate the system. If condition continues go to step
2 below.
2. Feed Water Pump is worn due to cavitation or fine particle debris and suspended solids abrasion and
requires re-building. Refer to Feed Water Pump troubleshooting later in this section.
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
150
100
200
PSI
250
50
0
300
section 6 page 8 of 38
Sea Recovery Ultra Whisper Rev. A
[16]
PREFILTER OUTLET
OPERATING PRESSURE
ETD INLET
DEVELOPED BY THE ETD
PRESSURE GAUGE
0 - 300 PSI
150
100
200
PSI
250
50
300
0
[18]
0 - 1500 PSI
600
800
1000
400
PSI
200
1200
0
1400

Advertisement

Table of Contents
loading

Table of Contents