Sea Recovery SRC Ultra Whisper Compact 200 Owner's Manual page 113

Table of Contents

Advertisement

Sea Recovery Ultra Whisper Rev. A
START-UP PROCEDURE OF A NEW Ultra Whisper System:
1. Ensure that the installation has been properly performed as per the instructions in Section 2 of this Owners Manual.
2. Ensure that the tube shipping plug has been removed from the Potable Water outlet port of the Water Control
Manifold (Compact System) or from the R.O. Membrane/Vessel Product Water Port [20] (Modular System) and
that all 1/4" and 3/8" product water tubes are connected, refer to Section 2 of this Owners Manual.
3. Reverse Osmosis Element: CAUTION: Some
systems are shipped WITHOUT
the Reverse Osmosis Membrane Element.
This is to accommodate, for example, Boat
Builders that install the system well in
advance of commissioning the boat and the
Sea Recovery System.
If the Reverse Osmosis Membrane Element has been installed there will be a Reverse Osmosis Membrane Element
Serial Number tag, illustrated above, attached to the R.O. Membrane/Vessel Assembly [20]. Find this Serial
Number tag adhered to the R.O. Membrane/Vessel Assembly [20] to ensure that the R.O. Membrane Element has
been installed.
If the R.O. Membrane Element Serial Number tag is missing or does not contain a serial number and date then
immediately contact the company that sold the system to you, or Sea Recovery. Provide Sea Recovery with the
System Serial Number and Model Number of this Ultra Whisper System.
WARNING: DO NOT attempt to operate the system without a Reverse Osmosis Membrane Element installed in the
system else extensive damage will result.
4. Ensure that the manual By-Pass lever
located on the side of the 3-Way Product
Water Solenoid Diversion Valve [26]
is positioned outward (away from the coil body).
5. Check each hose and tube connection to the System to
ensure that the installer has properly connected and
properly routed each hose and tube. Ensure that
there are no kinks or blockages in any of the hoses or
tubes leading to and from the Ultra Whisper System.
Improper routing and any blockage in any line causes
damage to the system. Do not rely on the
installer's word, check it yourself.
6. Make sure that the Electrical Power Source, boats
circuit breaker, to the System is switched "OFF".
Sea Recovery
Rancho Dominguez, California 90220 U.S.A.
Tel: 1-310-637-3400 ¦ Fax: 1-310-637-3430
Email: sales@searecovery.com
SERIAL NO:
2036330
--›
BRINE INLET END
FLOW:
DATE:
February 15, 2005
Section 3 Page 6 of 12

Advertisement

Table of Contents
loading

Table of Contents