Sea Recovery Ultra Whisper Rev. A
3. Ensure all Suction Hose connections use two hose clamps rotated 180 degrees with the screw heads facing the
same direction. Remove any flash on the Hose Barb fittings using fine sandpaper.
4. Ensure all High Pressure Hoses [19 & 21] have sufficient slack and are not pulled tight into a sharp or
immediate bend.