c. POSSIBLE CAUSE: BLOCKAGE IN THE PREFILTRATION.
1) If the "High/Low Pressure" Fault Lamp is illuminated, Press Reset Fault Switch.
2). Start the System
IF The Feed Pump Inlet Compound Vacuum/Pressure Gauge [5] registers normal (near or at 0 [zero] PSI, yet
the Prefilter Inlet Pressure Gauge [12] registers higher than normal while the Prefilter Outlet Pressure Gauge
[16] and Operating Pressure Gauge [18] registers lower than normal this would indicate that the Prefilter
Elements [13 & 14] are dirty and require replacement. This will cause low Feed Water flow and in turn low
Product Water flow. The High Pressure Switch [11] will open causing the System to shut down when the
Prefilter Elements become so dirty that the Prefilter Inlet Pressure Gauge [12] reaches 190 PSI. Correct the
condition as described below:
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
30
20
40
10
50
PSI
0
-30
70
IN HG
1. Clean the Plankton Filter Element [7]
2. Replace the 25 and 5 micron Prefilter Elements [13 & 14] with new Sea Recovery Prefilter Elements.
WARNING: Do not use third party prefilter elements, use only Sea Recovery Prefilter Elements.
WARNING: Do not use "string wound" or "fiber" prefilter elements. These type of elements are
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
150
100
200
PSI
250
50
60
300
0
Third party prefilter elements on the market do not properly fit, the seams fall apart,
they will allow by-pass resulting in premature fouling of the R.O. Membrane Element
and this will void the Sea Recovery Warranty.
designed for the Photographic Film Developing industry. When used in sea water they
will plug up rapidly in 1/10th or less the time causing frequent shut down of the system
and very frequent changing resulting in very high cost of maintenance and time
consuming frustration.
section 6 page 24 of 38
Sea Recovery Ultra Whisper Rev. A
[16]
PREFILTER OUTLET
OPERATING PRESSURE
ETD INLET
DEVELOPED BY THE ETD
PRESSURE GAUGE
0 - 300 PSI
150
100
200
PSI
250
50
0
300
[18]
0 - 1500 PSI
800
600
400
1000
PSI
200
1200
1400
0

Advertisement

Table of Contents
loading

Table of Contents