7. Open the front panel of the Main Power Enclosure. Check all electrical and electronic connections for proper wiring
and attachment. Refer to the wiring diagrams in Section 8 of this manual.
8. Ensure that the Installer has used the proper sized Power Wire and Feed Pump wire. Refer to Section 8 of this
Manual.
9. Close the Main Power Enclosure front panel.
10. Open the Sea Cock Valve [2].
11. Open any auxiliary Valve within the incoming Feed Line; Outgoing Brine Discharge Line; and Outgoing Product
Water Line.
WARNING: Any auxiliary Valve in these lines damages the Sea Recovery System if left closed during starting and or
operation of the System.
12. If the optional Clean Rinse Valves [36 & 37] are installed ensure that they are positioned properly for normal
operation. Refer to the Piping & Interconnect Diagram at the beginning of this Section 3.
13. Switch the Electrical Power Source to the "ON" position, boats circuit breaker.
14. FEED WATER PUMP [6] MOTOR ROTATIONAL CHECK: Ask an assistant to view the fan section of the Feed
Water Pump Motor [6] while you "Jog" this electric motor.
COUNTER CLOCKWISE
WHEN VIEWING
THE REAR (FAN END)
OF THE MOTOR
Press the "Start" switch, and then immediately after the Feed Water Pump starts press the "Stop" switch. Ensure
that the Feed Water Pump Electric Motor turned in the proper rotation as per the illustration above.
If the motor turned in the wrong direction, refer to the wiring diagrams in Section 8 to correct. To change rotation
in DC systems reverse polarity to the electric motor by interchanging the positive and negative power leads to the
motor. Then check the rotation again to ensure proper rotation.
WARNING: The feed water pump is a very close tolerance vane pump. It requires water for lubrication. Operating
this pump dry will damage it within 30 seconds. Prime the system with water up to the feed water pump inlet to ensure
that it is wet prior to starting.
15. To start the system press the "Start" Switch.
If the system automatically shuts off immediately or if after 20 seconds of operation, this may be due to a system
fault. Look at the Touch Pad to confirm whether a fault has occurred. If the "High/Low Pressure" Fault Lamp is
illuminated ensure that the System Feed Line is primed and that there is no air in the Feed Water Line. Press the
Fault Reset button on the touchpad and restart the system. Initial New System Commissioning may require
priming of the Feed Water up to the Feed Pump [6] Inlet and through the prefiltration section in order to build
sufficient feed water pressure to maintain operation.
HIGH/LOW PRESSURE FAULT LAMP EXPLANATION:
FEED WATER PUMP AND MOTOR ROTATION
Section 3 page 7 of 12
Sea Recovery Ultra Whisper October 2006
CLOCKWISE
WHEN VIEWING
THE FRONT
OF THE PUMP