e) If 12 VDC is not present at the din connector terminals then the cable connections may be loose, the
cable may be broken, or the control circuit may be defective. Check these components.
f) Check for 12 VDC at the connection points of the Diversion Valve Solenoid Coil on the Control
Printed Circuit Board terminals.
g) If 12 VDC is present while System is operating and while the "safe water" lamp on the Touch Pad is
illuminated green, then the Diversion Valve cable is loose at one of the connections or the cable is
defective.
h) If there is no voltage present while System is operating and while the "safe water" lamp on the
Touch Pad is illuminated green, then troubleshoot the Control Printed Circuit Board.
18. Ultraviolet Sterilizer [30]: The UV Sterilizer lamp emits a low frequency form of light. This light degrades and
looses intensity and ability to sterilize biological matter over approximately 4,000 hours of use. Therefore, the
lamp may remain lit, but requires replacement every 4000-8000 hrs. Refer to Page 34 of this section for
maintenance details.
CAUTION: Make sure that system power is turned off before beginning sterilizer maintenance. Ultra Violet light
is harmful to eyes and skin.
WARNING: High Voltage is generated from the Ultra Violet power supply and applied to the Ultra Violet Lamp.
Lamp Replacement:
a. Remove the four screws on the ballast box and remove lid.
b. Remove the rubber boot and carefully pull lamp out of the quartz sleeve.
c. Replace the lamp. During lamp replacement clean the quartz sleeve as well. The quartz sleeve should be
crystal clear and if it has discolored, it must be cleaned or replaced.
Quartz Sleeve Cleaning:
a. Remove the four screws on the ballast box and remove lid.
b. Remove the rubber boot and carefully pull lamp out of the quartz sleeve.
c. Unscrew and remove the two compression nuts (ballst box and view port).
d. Remove the O-ring on the view port side only.
e. With care pull the quartz sleeve out from the ballast box side.
f. Clean the quartz tube with water and a bottlebrush without moving the O-ring . Dry with a soft cloth.
Handle the quartz sleeve carefully.
Reassembly:
a. Replace old O-rings with new O-rings.
b. Insert the quartz sleeve (close-end first) through the ballast box passthru until O-ring contact passthru.
Screw on the ballast box compression nut. Insert view port O-ring and screw on view port compression nut..
c. Attach a new U.V. Lamp into the plug.
d. Slide the lamp into the Quartz Sleeve and install rubber boot over the compression nut.
section 7 page 31 of 39
Sea Recovery Ultra Whisper Rev. A