l. Press the "STOP" Switch.
m. Remove the temporary plug from the salinity probe tube connector.
n. Remount the salinity probe into its tube connector.
o. Operate the system to check for leaks and proper functioning.
15. Charcoal Filter [28]: A sulfurous (rotten egg) smell from the product water requires the replacement of the
Charcoal Element. Otherwise, the Charcoal Element should be replaced every 3 to 4 months. It is not
cleanable.
To replace the Charcoal Filter Element:
1. Unscrew the bowl counter clockwise.
2. Remove the Charcoal Filter Element from the bowl.
3. Remove the O-Ring from the top of the bowl and take care to not damage it.
4. Replace the Charcoal Filter Element with a new Sea Recovery element.
5. Wipe the O-Ring with a damp cloth.
6. Lubricate the O-Ring lightly using a sparingly amount of petroleum free O-Ring lubricant.
7. Place the O-Ring back onto the bowl.
8. Insert the new, Sea Recovery Charcoal Filter Element into the bowl.
9. Screw the bowl on clockwise.
10. Hand snug to seal the O-Ring, do not use a wrench or other tool to tighten, do not over tighten. Over
tightening will damage the threads in the bowl or housing and over tightening will cause removal to be
difficult.
16. pH Neutralizing Filter Cartridge replacement [29]
To replace the Prefilter Element:
1. Unscrew the bowl counter clockwise.
2. Remove the pH Neutralizing Element from the bowl.
3. Remove the O-Ring from the top of the bowl and take care to not damage it.
4. Replace the pH Neutralizing Element with a new Sea Recovery element.
5. Wipe the O-Ring with a damp cloth.
6. Lubricate the O-Ring lightly using a sparingly amount of petroleum free O-Ring lubricant.
7. Place the O-Ring back onto the bowl.
8. Insert the new pH Neutralizing Element into the bowl.
9. Screw the bowl on clockwise hand snug to seal the O-Ring, do not use a wrench or other tool to tighten, do
not over tighten. Over tightening may damage the threads in the bowl or housing and over tightening will
cause removal to be difficult.
section 7 page 28 of 39