4. Connect Pressure pick-up with Pressure Gauges with the supplied 20 feet (6 meters) of 1/4" (6.35 mm) O.D.
nylon tubing:
Step
from Outlet of
1.
Feed Pump [6] Pressure Pick Up Tee
2.
Inline Pressure Pick-Up Tee [8]
3.
Pressure Switch Manifold [9]
4.
Inline Pressure Pick-Up Tee [15]
to Inlet of
Inlet Compound Vacuum/Pressure Gauge [5]
located at the Prefilter [13 & 14] bracket'
pressure gauge -30-0-60
Pressure Switch Manifold [9]
located at the Prefilter [13 & 14] bracket
Prefilter Inlet Pressure Gauge [12]
located at the Control Panel
top pressure gauge 0-300 PSI
Prefilter Outlet Pressure Gauge [16]
located at the Control Panel
bottom pressure gauge 0-300 PSI
Section 2 Page 63 of 68
Sea Recovery Ultra Whisper v3.0 June 2008