d. POSSIBLE CAUSE: EXCESSIVE WATER FLOW, or EXCESSIVE PERCENTAGE OF RECOVERY.
Three components must be properly matched in order to attain acceptable operating pressure limits and
resulting Product Water Production Limits. The ETD [17], the Reverse Osmosis Membrane Element [20],
and the Feed Pump [6] Output Flow of water must all be matched. Upon leaving Sea Recovery's factory
at the time of shipment these components have been matched and tested together.
If the initial Sea Recovery customer (Distributor, Dealer, or Boat Builder) has mistakenly interchanged
one or more of these components this will cause a mismatch resulting in insufficient operating pressure,
insufficient product water flow, excessive operating pressure, or excessive product water flow. If one or
more of these components has recently been replaced it may have been replaced with the incorrect
component.
If the System is NEW and being operated for the first time, or if the one or more of the above mentioned
components has recently been replaced, check to ensure that the three components are properly matched.
Refer to pages 16 - 18 in this section.