Sea Recovery SRC Ultra Whisper Compact 200 Owner's Manual page 103

Table of Contents

Advertisement

Sea Recovery Ultra Whisper Rev. A
5. Connect High Pressure Hoses to and from the R.O. Membrane Pressure Vessel and the ETD using the two (2)
supplied High Pressure Hoses. Refer to illustrations below.
Step
from Outlet of
1. ETD [17] Port "P"
Pressure Outlet
2. R.O. Membrane Pressure Vessel [20]
MEMBRANE/VESSEL ASSEMBLY [20] CONNECTIONS:
Pressurized
Brine Water
Outlet
High Pressure Hose
From R.O. Membrane/Vessel
Assembly Outlet
To ETD Return Port "R"
ENERGY TRANSFER DEVICE (ETD) [17] CONNECTIONS
High Pressure Hose
From R.O. Membrane/Vessel
Assembly Outlet
To ETD Port "R"
Clear Braded 5/8" I.D. Hose
From ETD Port "S"
To Brine Discharge Tee [22]
Over Board Thru-Hull
1/4" O.D. Black Tubing
From R.O. Membrane/Vessel Assembly
Product Water Outlet
To Control Panel Product Water Flow Meter
Inlet (Bottom)
Feed Water Flow
"R"
"S"
Section 2 Page 64 of 68
to Inlet of
R.O. Membrane Pressure Vessel [20]
ETD [17] Port "R"
Pressure Return
To R.O. Membrane/Vessel
"P"
"E"
Clear Braded 5/8" I.D. Hose
From Prefilter [14] Outlet
Pressurized
Feed Water
Inlet
High Pressure Hose
from ETD Port "P"
To R.O. Membrane/Vessel
Assembly Inlet
High Pressure Hose
From ETD Port "P"
Assembly Inlet
To ETD Port "E"