Motor Rotation; Feed Water Pump Motor Electrical Specifications - Sea Recovery SRC Ultra Whisper Compact 200 Owner's Manual

Table of Contents

Advertisement

3. MOTOR ROTATION:

A.C. Systems: Refer to Feed Water Pump Electric Motor
nameplate for wiring connections and rotation notations.
DC Systems: The Feed Water Pump DC Electric Motor rotation is
polarity sensitive. If rotation is incorrect, check incoming polarity
and individual motor wiring. Jog the motor by pressing the Start
Switch and then quickly thereafter pressing the Stop switch.
Interchange Positive and Negative power lead wires at the Electric
Motor if rotation is reversed.
D. FEED WATER PUMP MOTOR ELECTRICAL SPECIFICATIONS:
12 & 24 VDC
Nominal Operating Amps
Maximum Motor Amps
Horse Power
Recommended Circuit Breaker
Minimum Size Power Wire AWG
Minimum Size Power Wire mm
115 & 230 VAC 60 Hz
Nominal Operating Amps
Maximum Motor Amps
Starting Amps
Horse Power
Recommended Circuit Breaker
Minimum Size Power Wire AWG
Minimum Size Power Wire mm
110 & 220 VAC 50 Hz
Nominal Operating Amps
Maximum Motor Amps
Starting Amps
Horse Power
Recommended Circuit Breaker
Minimum Size Power Wire AWG
Minimum Size Power Wire mm
NOTE:
Nominal Operating Amperage Will Increase if:
the Feed Water Temperature is Lower than 77º Fahrenheit / 25º Celsius.
the Feed Water Salinity is Greater than 35,000 PPM TDS (3.5% Total Dissolved Solids)
the R.O. Membrane Element becomes fouled
the R.O. Membrane Element is new and on the minus 15% side of the specifications
Nominal Operating Amperage Will Decrease if:
the Feed Water Temperature is Higher than 77º Fahrenheit / 25º Celsius.
the Feed Water Salinity is Less than 35,000 PPM TDS (3.5% Total Dissolved Solids)
the R.O. Membrane Element is new and on the plus 15% side of the specifications
UW 200
12V / 24V
16 / 8
28 / 13.4
.3
30 / 15
6 / 8
13 / 8
2
UW 200
115V / 230V
115V / 230V
5 / 2.5
6.6 / 3.5
25 / 12.5
.3
10 / 5
12
2
3
UW 200
110V / 220V
110V / 220V
4.8 / 2.4
5.2 / 2.6
26 / 13
.3
10 / 5
12
3
2
section 8 page 6 of 12
FEED WATER PUMP
FLOW RATE CODE
UW 300
UW 400
12V / 24V
12V / 24V
24 / 12
24 / 12
28 / 13.4
28 / 13.4
.3
.3
30 / 15
30 / 15
6 / 8
6 / 8
13 / 8
13 / 8
UW 300
UW 400
115V / 230V
5.3 / 2.7
5.3 / 2.7
6.6 / 3.5
6.6 / 3.5
25 / 12.5
25 / 12.5
.3
.3
10 / 5
10 / 5
12
12
3
3
UW 300
UW 400
110V / 220V
5.1 / 2.5
5.1 / 2.5
5.2 / 2.6
5.2 / 2.6
26 / 13
26 / 13
.3
.3
10 / 5
10 / 5
12
12
3
3
Sea Recovery Ultra Whisper Rev. A
SUCTION VACUUM/PRESSURE
INLET
PICK UP TUBE FITTING
OUTLET
5
UW 500
UW 600
24V
24V
24
26
20
20
.5
.5
25
25
6
6
13
13
UW 500
UW 600
115V / 230V
115V / 230V
7.2 / 3.6
7.5 / 3.7
8.6 / 4.3
8.6 / 4.3
46 / 23
46 / 23
.5
.5
10 / 5
10 / 5
12
12
3
3
UW 500
UW 600
110V / 220V
110V / 220V
7 / 3.5
7.3 / 3.6
7.4 / 3.7
7.4 / 3.7
44 / 22
44 / 22
.5
.5
10 / 5
10 / 5
12
12
3
3

Advertisement

Table of Contents
loading