Sea Recovery SRC Ultra Whisper Compact 200 Owner's Manual page 36

Table of Contents

Advertisement

Relief Kit. This kit,
consisting of low and
high
pressure hoses and fittings is connected between
the R.O. Membrane Pressure Vessel and ETD
during Winterizing and Membrane Cleaning to
relieve pressure at the R.O. Membrane.
36. Inlet Rinse Clean Valve *** used
in conjunction with the
Discharge Rinse Clean Valve
[37] simplifies the storage and
cleaning procedures by allowing
the operator to turn a valve
rather than disconnect a hose.
Also used for a manual fresh water flush if the
Automatic Fresh Water Flush System [33-35] is
not installed.
37. Discharge Rinse Clean Valve ***
used in conjunction with the
Inlet Rinse Clean Valve [36]
simplifies the storage and
cleaning procedures by allowing
the operator to turn a valve
rather than disconnect a hose.
38. Rinse/Clean Solution Container ** used to hold
rinse water, storage solution, winterization
solution, or cleaning solution may be any 5 gallon
or larger container portable or permanently
installed.
F. ELECTRONIC SUBSYSTEM measures water quality,
controls the direction of Product Water flow, Starts
and Stops the System, and contains the central
electrical connection point of the System. It also
ensures only potable Product Water passes into the
Product Water Storage Tank.
39. Salinity Controller The controller monitors the
Rinse/Clean Valve
40. Remote Controller *** allows for remote monitoring
41. Soft Start*** The soft start, used
Rinse/Clean Valve
Section 1 Page 13 of 16
Sea Recovery Ultra Whisper Rev. A
salt content of the product water via the Salinity
Probe [25], and signals the 3-Way Product
Diversion Valve [26] when Potable Water is being
produced. The 3-Way Product Diversion Valve
[26], Feed Pump Motor [6], Remote Control [40]
U.V. Sterilizer [30], and Soft Motor Starter [41]
are each governed by this Controller. This
enclosure also contains the high-voltage
components of the system. It serves as the
connection point for all the electrical systems such
as the motors, switches, and valves.
and controlling of the system.
only in AC (Alternating Current)
Single Phase systems reduces by
40% the initial startup amperage
required to start the Feed Pump
Motor [6] and in turn allows a
smaller sized KW generator to
start the system.