EXi: PolysixEX
TRANSPOSE
This controls the coarse tuning, in half-steps and cents, up or
down two octaves. You can modulate this smoothly via
AMS.
TUNE
This adjusts the pitch of the oscillators, in steps of 1/5 of a
cent, for a total range of +/- 1 semitone.
4-1h: EFFECTS
MODE
[OFF, CHORUS, PHASE, ENSEMBLE]
Switches the effect mode. Choose from chorus, phase, and
ensemble.
SPREAD
Adjusts the width to which the effect sound will be panned.
SPEED/INTENSITY
Adjusts the speed or intensity of the effect.
If MODE is set to Chorus or Phase, this adjusts the speed.
If Ensemble is selected, this adjusts the depth.
4-1i: Parameter Details
When you touch a knob or switch, a yellow square appears
around it, showing that it has been selected.
The Parameter Details area shows information for this
selected item, including its parameter group and parameter
name, its exact value, and its AMS assignments.
Individual parameters and AMS
PITCH BEND RANGE is not modulatable via AMS. The
PAN knob and a number of switches are modulatable by a
single AMS source, as described under "Pan knob and
Switches," below. The rest of the continuous knobs on this
page are modulatable via two AMS sources, as detailed
under "Knobs," below.
(Parameter group)
This shows the group of the parameter (such as VCO).
(Parameter name) [range depends on parameter]
This shows the name and exact value of the parameter. You
can edit the parameter value with any of the standard data-
entry controls.
Knobs
AMS
This selects a modulation source to control the selected
parameter. For a list of AMS sources, see "Alternate
Modulation Source (AMS) List" on page 1109.
Intensity
This controls the depth and direction of the AMS
modulation. For unipolar parameters, the range is the same
as that of the selected parameter, in both positive and
negative directions. For instance, if the parameter range is
0.00...10.00, the Intensity range will be -10.00...+10.00.
For bipolar parameters, including FILTER EG
INTENSITY, VCA ATTENUATOR, TRANSPOSE, and
TUNE, the range is twice that of the original parameter. For
instance, if the original parameter range is –24.00...+24.00,
338
[-24.00...+24.00]
[–5.00...+5.00]
[0.00...10.00]
[0.00...10.00]
[List of AMS Sources]
[range depends on parameter]
the Intensity range will be double that: –48.00...+48.00.
This allows full modulation of the parameter, regardless of
the initial setting.
In some cases, you can use this to modulate the parameter
outside of its original range, for a wider range of values.
Int Mod
You can modulate the main AMS Intensity from another
AMS source. This selects that source. For a list of AMS
sources, see "Alternate Modulation Source (AMS) List" on
page 1109.
Intensity
[range depends on parameter]
This controls the depth and direction of the Intensity Mod.
The result is summed with the main AMS Intensity to
produce the final modulation amount.
Pan knob and Switches
The PAN knob and the OCTAVE, WAVEFORM, SUB
OSC, VCA MODE, MG MODE, and EFFECTS MODE
switches can each be modulated from a single AMS source.
TEMPO SYNC, KEY SYNC, and BASE NOTE are not
modulatable.
AMS
This selects a modulation source to control the selected
parameter. For a list of AMS sources, see "Alternate
Modulation Source (AMS) List" on page 1109.
Intensity
[range depends on parameter]
This controls the depth and direction of the AMS
modulation. The range is the same as the selected parameter,
in both positive and negative directions.
v 4–1: Page Menu Commands
The number before each command shows its ENTER +
number-key shortcut. For more information on these
shortcuts, see "ENTER + 0-9: shortcuts for menu
commands" on page 153.
• 0: Write Program. For more information, see "Write
Program" on page 153.
• 1: Exclusive Solo. For more information, see "Exclusive
Solo" on page 153.
[List of AMS Sources]
[List of AMS Sources]