Section 3: Operation

Summary of Advanced: Lamp History Menu

• New Lamp: Activates the Lamp History window and text editing box for recording a new lamp's serial
number, which resets the lamp timer.
• Acknowledge Lamp Rotation: This button must be pressed to confirm that lamp rotation has been
performed.
• Lamp Type: Enter the lamp type.
• Serial Number: Enter the serial number of the newly installed lamp.
• Hours: Enter the number of hours logged on the newly installed lamp. If the lamp has never been used the
value should be 0.
• Date: Enter the date when the lamp was installed.
• Rotated: Specify whether or not the lamp has been rotated.
Detailed Lamp Logging
Detailed lamp operation information is captured in a log file located in the /var/log/ directory which is
accessible from the Web UI. The log file name consists of "lamp_" text, followed by the lamp serial number
and log file index number. For example, lamp_serialno_001.txt. If the lamp log file is over 500KB, the file will
be compressed and archived (e.g., lamp_serialno_001.gz). Lamp information will then get logged to a new file
where the index number gets incremented. When changing to a new lamp, the old log file will be compressed
and a new log file with the new lamp serial number will be created. In total, 20 compressed files will remain in
the /var/log directory where older compressed files will be deleted when this number is reached.

Advanced: Lens Menu

The Advanced: Lens menu enables advanced users to setup the primary lens, auxiliary lens, the MALM and
the ILS.
A
Intelligent Lens System: Calibrate ILS
B
Auxiliary Lens: Select the lens type from
the drop-down menu
C
Primary Lens: Select the lens type from
the drop-down menu
3-40
Figure 3-29 Advanced: Lens Menu
D
Serial Number: Record the serial number for the
selected primary lens
E
Serial Number: Record the serial number for the
selected auxiliary lens
F
Motorized Auxiliary Lens Mount: Calibrate M-MALM
CP2000-M/MR User Manual