Appendix A: Serial API
Table A.1 Function Codes
EXAMPLES:
(LID?L) list supported lamp IDs
(LID?) get the lamp id for installed lamp
(LID 4) or (LID "CDX-30") set the lamp ID for installed lamp
LampLOC™ Module (LLM)
DESCRIPTION
Allows adjustment of lamp position to optimize intensity and uniformity of the optical system. This is referred to as the
LampLOC™ feature and can be done automatically or manually.
SUBCODE
AUTO
CALI
MTRX
MTRY
MTRZ
None
STAT
EXAMPLES:
(LLM+MTRX 100) Move motor-X to position 100
(LLM+AUTO 1) Do LampLOC automatically
(LLM+AUTO 0) Abort LampLOC, it will restore the motors to previous position automatically
Lens Manual Override Global (LMO)
DESCRIPTION
LENS MANUAL OPERATION
Enable/disable the
SUBCODE
None
EXAMPLES:
(LMO 1) Enable LMO 
(LMO 0) Disable LMO
Adjust all lens position parameters simultaneously (LMV)
DESCRIPTION
Adjust all lens position parameters simultaneously.
SUBCODE
None
A-10
DESCRIPTION OF USE
Set to 1 to do LampLOC™ automatically. It will do calibration first, then
moving x,y,z-motor to find the maximum brightness.
Set to 1 calibrate all 3 motors. I.e. Move all 3 motor to default position.
Note: (LLM +CAL?) will return 1 if calibration is running and 0 if 
calibration is finished.
Moving X-axis motor manually, data range: - 500 to 500.
Moving Y-axis motor manually, data range: - 500 to 500.
Moving Z-axis motor manually, data range: - 500 to 500.
Not available.
Provides feedback (status) on the progress of the Auto mode. Read only
command, data range from 0 to 100, where 100 indicates the lampLOC is
finished.
mode, global control
DESCRIPTION OF USE
Not available.
DESCRIPTION OF USE
(LMV <lho> <lvo> <zom> <fcs>)
CP2000-M/MR User Manual