Section 3: Operation
• Fan Mode: Displays the operational mode of the fans.
• Date: Reset date as desired. Click on the calendar icon to display a calendar. Select a date and press the Set
button to apply the change.
• Time: Reset time displayed as desired. Choose from 24-hour or standard 12-hour formats. Time is always
displayed on each window in the chosen format. Save format with the Set button.
• Time Zone: Select the time-zone.

Advanced: Lamp Menu

The Advanced: Lamp menu provides controls for optimizing lamp alignment (LampLOC™), maintaining a
consistent light output over time (LiteLOC™), or setting a precise power level for the lamp. Two read-only
areas display related lamp performance details - the side bar graph represent the current light output and, if
LiteLOC™ is enabled, a heavy line shows the chosen LiteLOC™ setting.
A
Do Auto: Auto LampLOC adjustment
B
Lamp Positioning Controls (horizontal/vertical/for-
ward/back)
C
Set: Used to set and maintain consistent light out-
put, as indicated in the Set light level window
(read-only)
D
Lamp Power: Adjustable from 50-100% if LiteLOC
is not in use

Summary of Advanced: Lamp Menu

• Lamp Power: Enabled only when LiteLOC™ is disabled, Lamp Power indicates what percentage of power
to supply to the lamp, automatically overriding the any LiteLOC™ setting that may be in effect. This causes
the bar graph to rise or fall as Lamp Power is increased or decreased, but the LiteLOC™ red line and Set
values will not change unless Set is pressed (defining a new LiteLOC™ setting) and enabling LiteLOC™
checkbox). Lamp Power range = 50% - 100% representing the percentage of the lamp's power rating.
• Enable: Enter a checkmark to enable LiteLOC™ for the current channel based on the value in the Set Light
Level window.
• Set (Brightness): Automatically enables LiteLOC™ and the current brightness level will be maintained as
long as possible. Arbitrary units-of-measure shown in the Set Light Level window, not lumens or fL.
3-38
Figure 3-27 Advanced: Lamp Menu
E
Enable LiteLOC function
F
Lamp: Read-only lamp information
G
Light: Reading from light sensor
H
Red bar indicates LiteLOC setting (desired brightness)