Table A.1 Function Codes
EXAMPLES:
(DEF 111) - Restore all preference, configuration, option, and unsaved controls to default 
(DEF+USER 111) - Clear all users and restore factory default user 
(DEF+CONF 111) - Reset all configuration controls 
(DEF+PREF 111) - Reset all preference controls 
(DEF+UNSV 111) - Reset all unsaved controls 
(DEF+CHAN 101) - Restore Channel 101 
(DEF+CHAN 0) - Restore all channels 
(DEF+CHAN?) - Shows last channel defaulted or -1 on failure
Data Logging (DLG)
DESCRIPTION
Set data logging level.
SUBCODE
None
EXAMPLES:
Levels are:
0 = Minimum logging of activities. Logging system errors and power on/ off, lamp on/off, user login/logout only
1 = standard logging (errors plus select operations - shutter on/off, changing channels)
2 = Maximum logging. All activities are logged
(DLG1) set current logging level to 1
(DLG?) get current logging level. Response is (DLG!001)
Data Format (DTF)
DESCRIPTION
Select data packing format for selected input. Available data formats depends on current input port (as selected by SIN).
NOTE: Valid options when SIN = 0 ("292-A") or 1 ("292-B"): 000 "422 Unpacked 10Bit" 001 "422 Packed 12Bit" 002
"444 Packed 10Bit" 003 "444 Packed 12 Bit".
Valid optiosn when SIN=2 "292-Dual": 010 "422 Unpacked 10Bit O/E Pixels" 011 "422 Unpacked 10Bit, O/E Lines" 012
"422 Packed 12Bit, O/E Pixels" 013 "422 Packed 12Bit, O/E Lines" 014 "444 Unpacked 10Bit" 015 "444 Packed 10Bit,
Mixed" 016 "444 Packed 10Bit, O/E Pixels" 017 "444 {acked 12Bit" 018 "422 Unpacked 10Bit O/E Frames"
Valid options when SIN=3 ("DVI-A") or 4 ("DVI-B") 020 "Unpacked 8Bit" 021 "Packed 10Bit" 022 "Packed 12Bit"
Valid options when SIN=5 ("DVI-Twin"): 030 "Twin packed 10Bit"
SUBCODE
Cxxx
None
EXAMPLES:
DTF?) get current data format 
(DTF?L) Show entries on the list 
(DTF 1) or (DTF "422 Packed 12Bit") Set current data format to 1 (292: 422 Packed 12Bit) 
(DTF+C108?) get data format on channel 108 
(DTF+C108 20) or (DTF+C108 "Unpacked 8Bit") use data format 20 (DVI: Unpacked 8Bit) on channel 1
Enable Error Messages (EME)
DESCRIPTION
Enable error messages.
SUBCODE
FANF
CP2000-M/MR User Manual
020-100123-07 Rev. 1 (12-2009)
DESCRIPTION OF USE
There are 3 levels for data logging.
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Select data format for current channel.
DESCRIPTION OF USE
0 - No Fan Fail warning will be generated; 1 - Fan Fail warning will be
generated.
Appendix A: Serial API
A-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp2000-mr

Table of Contents