Admin: Tcgd Menu - Christie CP2000-M User Manual

Hide thumbs Also See for CP2000-M:
Table of Contents

Advertisement

Section 3: Operation
• Save: This button collects the current color values entered for Measured (MCGD), where you can save
them as a new OnSite MCGD file or as a different MCGD file with a different name. A new OnSite file
overwrites any previously defined OnSite file and will be the default reference point for all future color
processing—the old OnSite file cannot be recovered. By default, the projector refers to OnSite data to
calculate the corrections needed to achieve a known target color performance standard in the future.
However, if the site requires more than 1 set of native MCGD values (such as when a wide angle converter
lens is swapped in or out), a new MCGD file can be created with a different file name. Each setup (channel)
can then use any desired MCGD file as the basis for the color corrections needed for a target color. MCGD
files are chosen in the Channel: Page 2 menu. NOTE: User created MCGD files can be deleted only by
using Christie's licensed DLP Control Application software.
• Restore: This button enables users to return to the gamut menu settings that were present when the menu was
opened. The Restore button is disabled unless the Test button was used. To cancel new MCGD settings and
return to the previous MCGD settings, the new settings must be tested (via Test button), but not yet saved. If
not yet tested, either leave the menu and cancel the settings as requested by the dialogue box, or attempt to
save but cancel out of it. If the new OnSite file has already been saved the old OnSite file cannot be restored.

Admin: TCGD Menu

The Admin: TCGD menu allows users to modify or create custom Target Color Gamut Data (TCGD) files for
new color gamut performance and set how closely to match the target white.
A
Gain: Adjust luminance
B
Enable to display a particular color
C
XY: Record XY coordinates for each color
D
Target TCGD: Save settings to a new tar-
get file
E
White Tolerance: Enable & disable toler-
ance (a tolerance discards less light)
3-50
Figure 3-40 Admin: TCGD Menu
F
Save
G
Restore: Cancel unsaved screen settings and
display previous saved settings
H
Test: Preview settings in display without saving
I
Define XY coordinates for 4 corners