Table A.1 Function Codes
EXAMPLES:
(RAL 0) Disable remote serial protocol access for all Ethernet ports
(RAL?) Get access level for Ethernet ports (RAL!0)
(RAL+PRTA 2) Set remote serial protocol access level on port A to free access
(RAL+PRTA?) Get access level (RAL+PRTA!2)
Screen Format (SCF)
DESCRIPTION
Select Screen format file which describes the geometry for the output image.
SUBCODE
Cxxx
FULL
None
EXAMPLES:
(SCF+C108 "FLAT") Use file "FLAT" on channel 108
(SCF+C108?) get screen file name on channel 108
(SCF?L) list all available entries of screen control
Shutter/Douser (SHU)
DESCRIPTION
Open/Close shutter/douser
SUBCODE
None
EXAMPLES:
(SHU 1) close shutter
(SHU 0) open shutter
(SHU?) get current status of shutter
Select Input (SIN)
DESCRIPTION
Select Input Port. Selecting input port will reset the list and default data of DTF control. Use index number or text description
to select input port. Available options are: 000 "292-A" 001 "292-B" 002 "292-Dual" 003 "DVI-A" 004 "DVI-B" 005 "DVI-
Twin" 006 "IPM-INP DVIA" 007 "IPM-INP DVIB" 008 "IPM-INP DVIT" 009 "IPM-CHA DVIA" 010 "IPM-CHA DVIB"
011"IPM-CHA DVIT"
SUBCODE
Cxxx
None
CP2000-M/MR User Manual
020-100123-07 Rev. 1 (12-2009)
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Selects the full output screen.
Select screen file for the current channel.
DESCRIPTION OF USE
Select douser position 0 - douser removed from optical path 1 - douser
blocking optical path.
DESCRIPTION OF USE
Replace xxx with the channel number. Valid Range is 101 - 164.
Select input for current channel.
Appendix A: Serial API
A-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp2000-mr

Table of Contents