His-Lamp History - Christie Boxer 30 Technical Reference

Serial api commands
Hide thumbs Also See for Boxer 30:
Table of Contents

Advertisement

(GIO+STAT?)
Result:
(GIO+STAT!"LLLLLLL")
All inputs are low.
Set the status of the general purpose outputs:
(GIO+STAT "HXLHLLL")
Result:
Pins 1 and 4 are set to high; pin 2 has no change; Pins 2, 5, 6, and 7 are set to low.
Get the direction for the individual pins:
(GIO+CNFG?)
Result:
(GIO+CONFG!"IIIIIII")
HIS–Lamp History
Retrieves a history of lamps installed in the projector, including the currently installed lamp.
Each entry indicates lamp identification as well as various usage statistics collected while the lamp was
installed.
The list is in reverse chronological order—meaning the first entry describes the current lamp, followed
by the next most recent lamp, and so on, up to a maximum of 50 total entries.
Commands
Command
Description
HIS?
Returns a list of entries in the lamp history.
(Read-only)
Each entry has the following format:
<entry number> <install date> <serial #>
<lamp type> <strikes> <failed strikes>
<failed re-strikes> <unexpected lamp offs>
<pre-installation hours> <total lamp
hours>
HIS+LMP1?
Returns all the entries found in the lamp
memory module. (Read-only)
HIS+LMP2?
Each entry has the following format:
HIS+LMP3?
<entry number> <install date> <serial #>
HIS+LMP4?
<lamp type> <strikes> <failed strikes>
HIS+LMP5?
<failed re-strikes> <unexpected lamp offs>
HIS+LMP6?
<pre-installation hours> <total lamp
hours>
Boxer 30 Technical Reference–Serial API Commands
020-102096-08 Rev. 1 (08-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Serial API commands
Values
entry number = Unique number identifying
the entry
install date = Date that the lamp entry was
created
serial # = Serial number of the lamp (an
arbitrary string)
lamp type = Type of lamp used
strikes = Number of lamp strikes performed
for this entry
failed strikes = Number of failed strikes that
occurred for this entry
failed re-strikes = Number of times the
lamp failed a re-strike for this entry
unexpected lamp offs = Number of times
the lamp unexpectedly turned off for this
entry
pre-installation hours = Number of hours
that this lamp has been on, prior to being
installed in the projector