Christie CP2000-M User Manual page 139

Hide thumbs Also See for CP2000-M:
Table of Contents

Advertisement

Table A.1 Function Codes
EXAMPLES:
(BAK+CONF 1) Backup all configuration controls
(BAK+PREF 1) - Backup all preference controls
(BAK+USER 1) Backup all users
(BAK+INTR 1) Run interrogator enhanced
(BAK+INTR 0) Run interrogator normal
(BAK+CFIL?)(BAK+CFIL!"http:192.168.0.0/backup/config_model_sub_serial_date_time.tar")
(BAK+PFIL?)(BAK+PFIL!"http:192.168.0.0/backup/pref_model_sub_serial_date_time.tar") 
(BAK+UFIL?)(BAK+UFIL!"http:192.168.0.0/backup/user_model_sub_serial_date_time.tar") 
(BAK+IFIL?)(BAK+IFIL!"http:192.168.0.0/backup/intr_model_sub_serial_date_time.tar") 
(BAK+CHAN 1) - Backup all channel controls
(BAK+HFIL?)(BAK+HFIL!"http:192.168.0.0/backup/channel_model_sub_serial_date_time.tar")
Baud Rate (BDR)
DESCRIPTION
Set the baud rate for a serial communications port.
SUBCODE
PRTA
EXAMPLES:
(BDR+PRTA 6) Set baud rate on port A to 115200 bits per second
(BDR+PRTA?) Get baud rate (BRD+PRTA! "115200")
Control Display Panel settings (CDP)
DESCRIPTION
Enable error messages.
SUBCODE
BACK
CONT
EXAMPLES:
(CDP+CONT 60) change the contrast level to 60%
(CDP+CONT?) requests current contrast level. Example response is (CDP+CONT!50)
(CDP+BLACK 0) disable the backlight
(CDP+BLACK 100) set the backlight to full brightness
Channel (CHA)
DESCRIPTION
Select Channel configuration to use. Channel range is 101 to 164. Channel configuration sets the input routing and image
processing options for input signals.
SUBCODE
None
CP2000-M/MR User Manual
020-100123-07 Rev. 1 (12-2009)
DESCRIPTION OF USE
Set the baud rate on port A. Rates can be 1200,
2400,9600.19200,38400,57600 or 115200
DESCRIPTION OF USE
0 - 100. CDP Backlight Brightness level (both screen and key backlights).
0: disable backlight.
0 - 100. CDP Contrast level.
DESCRIPTION OF USE
Select Channel. Range 101 - 164.
Appendix A: Serial API