enclosure set temperature
To set the temperature threshold on a specific SAF-TE enclosure
management device, use the enclosure set temperature
command. Typically, an enclosure management device contains
individual temperature sensors.
With this command, you can set a temperature threshold so that the
enclosure management device alerts you if one or more of the
temperature sensors exceeds the threshold.
Syntax
enclosure set temperature {enclosure} {degree}
Parameters
{enclosure}
Specifies the ID associated with the enclosure management
device on which you want to set a temperature threshold. For
this version, the controller supports a maximum of eight
enclosure management devices on each bus.
{degree}
Specifies the temperature (in degrees Fahrenheit) at which you
want to set the threshold for this enclosure management
device. You can specify from 0 to 255 degrees Fahrenheit.
The default is 120 degrees Fahrenheit.
Examples
Before setting the threshold temperature, you might want to use the
enclosure show temperature command to determine the
current temperature(s). As the following example shows, the current
temperature is 70 degrees Fahrenheit and the threshold setting is
120 degrees Fahrenheit:
Enclosure Sensor Temperature Threshold Status
--------- ------ ----------- --------- --------
0
0
70 F
The following example sets the threshold temperature associated
with enclosure management device 0 to 100 degrees Fahrenheit:
enclosure Commands
120
NORMAL