Adaptec SCSI RAID Software Reference Guide

Parameters

{container}
Specifies the ID number (0 to 63) of the array (mirror set or
multilevel array of mirror sets) to split into two separate
arrays.

Examples

Before splitting a mirror set or a multilevel array of mirror sets, use
the container list command to obtain information about any
existing arrays. As the following example shows, there is one
existing array (array 0, a mirror set) on this controller at the time the
mirror set is split:
AAC0>container list
Executing: container list
Num
Total
Oth Stripe
Dr Label Type
Size
Ctr Size
-- ----- ------ ------ --- ------ ------- ------ -------------
F: 0
Mirror 10.0MB
The following example shows how to split a mirror set:
AAC0>container split 0
Executing: container split 0
container 1 created
On UNIX systems, the message displayed after you execute the
container split command includes the root special file
associated with the newly created split array.
5-118
Scsi
Partition
Usage
C:ID:L Offset:Size
NTFS
0:02:0 64.0KB:
0:02:0 10.0MB:
10.0MB
10.0MB