Related Information - Adaptec RAID 2120S Software Reference Manual

Scsi raid
Hide thumbs Also See for RAID 2120S:
Table of Contents

Advertisement

The Type column displays the Volume array type for the three
underlying volume sets.
The Total Size column displays the sizes of the arrays. Note
that the underlying arrays are each 15.0 MB and array 0's size
is the total of the two underlying arrays.
The Scsi C:ID:L column displays the SCSI channel number,
SCSI device ID, and SCSI logical unit number for the
underlying arrays. In the example, array 63 resides on disk
0:02:0, array 62 resides on disk 0:03:0, and array 61 resides on
disk 0:04:0.
The Partition Offset:Size column displays the offset and size
for the underlying arrays' partitions. In the example, arrays 63,
62, and 61 have 64.0 KB offsets and 15.0 MB sizes.
If a partition is dead, the ":" (colon) in the Partition Offset:Size
column changes to a "!" (exclamation point). See the disk
remove dead_partitions
more information on dead partitions.
As stated previously, you can now use the container create
mmirror command to make a promoted array an array of mirror
sets.

Related Information

container commands:
container create mmirror
container create volume
container list
disk commands:
disk remove dead_partitions
(page
7-9)
(page
5-9)
(page
5-35)
(page
5-54)
(page
container Commands
command for
7-9)
5-71

Advertisement

Table of Contents
loading

This manual is also suitable for:

2200sWorkstation xw6000Xw8200 - workstation - 1 gb ram