Terminal block 2
GT16H-CNB-42S
Terminal block 2
Terminal No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
■Wiring to the terminal block
Terminal screws are M3.
Wire as described below.
Do not tighten the terminal screws with a torque outside the specified range.
Doing so can cause a failure or malfunction.
3.2(0.13)
6.2(0.24)
or less
3.2(0.13)
6.2(0.24)
or less
Wire size
Solderless terminal
Tightening torque
■Installing and removing of external cable
When installing or removing the external cable from the connector conversion box, make sure that the power switch is turned
OFF.
Connect the external cable with the connector conversion box in the same procedure as connecting the external cable with
Handy GOT.
Refer to the following.
Page 313 Installing and removing of external cable
Signal name
SW-COM
SW1
SW2
SW3
SW4
SW5
SW6
KSW-COM
KSW1
KSW2
DSW1
DSW1
DSW2
DSW2
Terminal
Solderless
screw
terminal
When wiring one cable to
one terminal
2
For power supply: 0.75 mm
or more, For grounding: 2 mm
Solderless terminal for M3 (Applicable solderless terminal: RAV1.25-3, V2-N3A, FV2-N3A)
0.5 N•m to 0.8 N•m
Application
For Operation switch
For Keylock switch
For Grip switch
Terminal
Solderless
screw
terminal
When wiring two cables to
one terminal
Unit: mm (inch)
2
or more
7 OPTION AND COMMUNICATION CABLE FOR HANDY GOT
7.1 Connector Conversion Box
7
279