Power Wiring; Power Wiring And Grounding - Mitsubishi Electric GOT2000 Series Hardware User Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

9.2

Power Wiring

Power wiring and grounding

GOT power is supplied from the external power.
In addition, the following table shows the input power supply voltage and the consumed current.
Item
Input power supply voltage
Power consumption
At backlight off
Inrush current
Example of feeding with external power
Connect the external cable to the external power.
24+ COM
Grounding
(100
or less)
*1 Cautions for grounding with the input power
■When the input powers are the same
External
power
PLC
supply
Grounding
(100
or less)
When the input powers of the PLC main unit and external power (24VDC) are the same, connect the FG cable of the GOT
and the ground terminal of the PLC (
■When the input powers are different
AC200V
AC100V
External
PLC
power
supply
Grounding
(100
or less)
When the input powers are different (PLC: 200VAC, Power: 100VAC), connect the ground terminal (
cable of GOT separately and carry out the independent grounding.
Specifications
GT2506HS-VTBD
24VDC(+10% -15%)
11.6W or less (480mA/24VDC)
8.2W or less (340mA/24VDC)
30A or less (at max. load) 2ms
To the Handy GOT operation switch
X0
X1
X2
PLC
Handy
GOT
FG
) and carry out the grounding.
Handy
GOT
FG
GT2505HS-VTBD
8.4W or less (350mA/24VDC)
7.0W or less (290mA/24VDC)
Handy GOT
X3
X4
FG 24V-
*1
Grounding
(100
or less)
9 HANDY GOT POWER WIRING AND SWITCH HANDLING
24V+
External
power supply
) of PLC and the FG
9.2 Power Wiring
9
333

Advertisement

Table of Contents
loading